2.6 Dip Switch Setting
Termination and Master/Slave: Set the switches according to your configuration.
Figure 7: Keyboard DIP switches
2.7 Multiplexer Configuration
Duplex Setup:
NOTE: Multiplexers to be controlled by the keyboard controller require a new ROM version. The new multiplexer ROM accepts control
instructions from the keyboard controller. If your multiplexer ’s serial number is „M104xxxx” or higher, then it is ready to accept control
instructions. Alternately, you can check the status of your multiplexer by pressing the Menu key of the multiplexer and then selecting
item 9. If you see the „** Protocol” option line in the Communication Setup menu, your multiplexer has the new ROM, and you do not
need to replace the ROM. If your multiplexer has the old ROM version, contact your distributor on how to get new a ROM.
CAUTION: Before opening the multiplexer, make certain you are working on an antistatic work surface and that you are wearing a grounding wrist
strap. Also, be very careful to orient the ROM chip correctly and not bend any of the pins.
NOTE: Replace the multiplexer firmware with the new multiplexer ROM (U45) as follows; remove the top cover of the multiplexer, and locate the
ROM (U45). Before removing the ROM, note the orientation of the ROM. After removing the old ROM from the socket, insert the new ROM.
Be careful to orient the new ROM the same as the old ROM. (Refer to the Multiplexer instruction manual.)
Set the multiplexer functions as follows: (Press the Menu key of the multiplexer to enter the Unit Options menu.)
Unit options:
Unit number 001 (first Mux) or 002 (second Mux)
Communication type RS-485
Baud rate 9600 bps
PORT ON
** Protocol ** B (If you see this line, the multiplexer has the new ROM)
** The old ROM version does not show Protocol selection option.
Multiplexer alarm inputs will function normally, but the Dome controller has no way of knowing about alarms wired to the Multiplexer. If a Dome preset is
required for such an alarm, you must connect the same alarm input to both the multiplexer and Dome.
Triplex setup:
Unit setup network type RS 485
Baud rate 9600 bps
Unit address 001 ~ 128
Protocol B1
NO. SETTING DESCRIPTION
1
ON
DOME1 Termination
OFF
2
ON
DOME2 Termination
OFF
3
ON
J-Box Data2 Termination
OFF
4~6
OFF
(Reserved)
7
ON DOWNLOAD ON
OFF
DOWNLOAD OFF
8
ON Slave
OFF
Master