35
6.4 DVR5 protocol for the DVR for the version 3.1.0 and over Installation of the DVR5 protocol when one DVR is used.
NOTE: When you set the protocol to DVR5, the keyboard operates as the DVR’s keyboard only you must install domes to the DVR only.
RS-232
When you control the PTZ camera by the DVR, follow as below.
1. Connect RS-232 cable between RS-232 Port of DVR and DVR port of the J-box. (This connection enables DVR control remotely from KBD controller)
2. Connect RS-485 cables between the DVR and PTZ cameras.
3. Connect the power jack to the power port of the keyboard.
A. Input password (Factory setting is
9 9 9 9)
B. Open the menu of the KBD controller by pressing
CTRL + MENU key.
C. Set as below in Network menu.
NOTE: The baud rate of DVR/AUX should be the same as one of the RS-232 of the DVR
4. How to setup DVR:
D. Switch the DVR on.
E. Enter the Menu according to the DVR’s instruction manual.
F. Change the Port to „RS-232” of the remote control in the devices menu.
G. Confirm matching the setup of RS-232 with the keyboard.
Ex: Baud Rate: 9600, Data Bit: 8, Stop Bit: 1, Parity: None)
H. Change the Remote Control to „Remote Control2” in the devices menu.
I. Change the Port to „RS-485” in the PTZ menu of the camera of the devices menu.
J. Confirm matching the setup of RS-485 of the PTZ menu with PTZ cameras.
K. Set the PTZ menu according to PTZ cameras.
NOTE: The baud rate of all PTZ cameras should be used one speed type (ex. All 9600 or all 2400)
NOTE: The product of FASTRAX should be used „FASTRAX2”
L. Set the ID number according to PTZ cameras.
M. Set the system ID number to 1.
Set Baud Rate
1. DOME1: 9600
2. DOME2: 9600
3. RS-232: 9600
Com Ports
1. DOME1: NONE
2 DOME2: NONE
3. RS-232: DVR5