14
Example 2: Multi/Single user system with 28~31 Cameras and two Multiplexers
Dome ID Mux 01
01 –> Cam 1
02 –> Cam 2
03 –> Cam 3
04 –> Cam 4 ID Mux 02
05 –> Cam 5 17 –> Cam 1
06 –> Cam 6 18 –> Cam 2
07 –> Cam 7 19 –> Cam 3
08 –> Cam 8 20 –> Cam 4
09 –> Cam 9 21 –> Cam 5
10 –> Cam 10 22 –>
Cam 6
11 –> Cam 11 23 –>
Cam 7
12 –> Cam 12 24 –>
Cam 8
13 –> Cam 13 25 –>
Cam 9
14 –> Cam 14 26 –> Cam 10
15 –> Cam 15 27 –> Cam 11
16 –> Cam 16 28 –> Cam 12
Aux 4 Cam 13
Aux 3 Cam 14
Aux 2 Cam 15
Aux 1 Cam 16
Main Keyboard
Slave Keyboard 1
Slave Keyboard 2
Slave Keyboard 3
Aux 1
Aux 2
Aux 3
Aux 4
Figure 10: Two Muxs configuration
Master KBD controller
MUX CONFIG. PAGE : 01
CAM MUXA IN OUT MUXB IN OUT
001 : 01 01 –> 01 02 16 –> 01
002 : -- -- –> -- -- -- –> --
003 : -- -- –> -- -- -- –> --
004 : -- -- –> -- -- -- –> --
005 : -- -- –> -- -- -- –> --
006 : -- -- –> -- -- -- –> --
007 : -- -- –> -- -- -- –> --
008 : -- -- –> -- -- -- –> --
ON : AUTO OFF:DEL. SAVE:PGM ESC
Slave-n KBD controller
MUX CONFIG. PAGE : 01
CAM MUXA IN OUT MUXB IN OUT
001 : 01 01 –> 01 02 16-n –> n+01
002 : -- -- –> -- -- -- –> --
003 : -- -- –> -- -- -- –> --
004 : -- -- –> -- -- -- –> --
005 : -- -- –> -- -- -- –> --
006 : -- -- –> -- -- -- –> --
007 : -- -- –> -- -- -- –> --
008 : -- -- –> -- -- -- –> --
PRESS ESC-KEY TO EXIT
Picture of selected camera by pressing No. + CAM is automatically switched to specific user (One of 4 users) monitor. Max No. of camera inputs depends
on No. of Keyboards (No. of user). Maximum of 31 cameras can be attached for single user configuration. In the case of a four user (Main, 3 Slave Keyboard)
system, 28 cameras can be attached to a system.
Camera selection is done by pressing 1, 2, 3, .....17, 18.... 27, 28, (29, 30, 31 + CAM
ID of First MUX is 01 and ID of second is 02. Changing the screen format of each Mux is possible after selecting the MUX to be controlled by pressing
1 or 2 + MUX.
Alternatively after 1~16 camera selection, ID 01 Mux is in control. After 17~31 camera selection, ID 02 Mux can be controlled by the user.
If the user wants to connect all 32 cameras, configure Spot(AUX) auto switching methods that will be the same as single Mux system. See example 1.
But first group of 16 cameras goes to Spot (AUX) of first Mux. And second group of 16 cameras goes to Spot (AUX) of second Mux. That is, Spot (AUX) monitor
is not inter changeable. Yet, camera ID should be continuous No. 1, 2, ... 32 and camera selection is done by pressing 1 ~ 32 + CAM.
Where n = ID of Slave Keyboard