24
ALARM SCHEDULE
Alarm Schedule Setup Screen
ALARM SCHEDULE PAGE : 01
CAM ALARM AUX MACRO
002 12345678 64 8
--- – – – –
--- – – – –
--- – – – –
064 – 2---56 – 8 –
--- – – – –
--- – – – –
--- – – – –
ON : INS. OFF : DEL. PGM ESC
Alarm Schedule has 8 pages. All 8 alarm inputs of 64 dome cameras can be used to activate programmed Macro.
Cam
Camera to be relayed to the alarm box
Alarm
1, 2, 3 ~ 8 – Select alarm Input to be relayed.
Aux
1, 2, 3 ~ 64 – Relay Output No. of alarm box.
MACRO
1, 2, 3 ~ 8 – Programmed macro to be executed by activated alarm.
ON key
Insert row to be newly inserted.
OFF key
Delete row not used.
PGM key
Save And Exit.
ALARM HISTORY
Alarm History Screen
ALARM HISTORY PAGE : 01
CAM ALARM DATE TIME
005 12-4- JAN-30-04 16:00:37
002 0XFF JAN-29-04 16:59:33
007 COMM. JAN-29-04 09:50:23
---
---
---
---
---
OFF : CLEAR HISTORY ESC : EXIT
Alarm History has 32 pages and is capable of displaying 256 events.
Cam
ID of alarm activated dome
Alarm
1, 2, 3 ~ 5 – In case of less than 5 alarm, No. represents activate alarm inputs.
0XFF – In case of more than 5 alarms, corresponding digits are set to 1.
COMM.
When communication error occurred